pnsCertificate

PNS CERTIFICATION

Philippine National Standard Certification

The approval of Pneumatic tyres and inner tubes for Motor vehicles and their trailers imported/manufactured/sold in Philippine market.

Applicable PNS Regulations

  • PNS 25:1994 for Pneumatic Tires (covers with PC, LT & TB)
  • PNS 30:2000 for Inner tubes

Those are the ground rules/regulations as follow:

  • DTI, DAO No 4 (Department Administrative Order, Series of 2000): Mandatory Philippine National Standards
  • DTI, DAO No 4 (Department Administrative Order, Series of 2008): Market Monitoring (Random Sampling/Testing from Market)
  • Application: Electrically through PCIMS by each Importer

Certification Body (Authority)

BPS (Bureau of Philippine Standards) under DTI (Department of Trade and Industry)

Testing Laboratories Accredited by BPS

  • PHILIPPINE GEOANALYTICS, INC., (PGA), #85 Kamuning Road, Kamuning Dist. 1V,Quezon City, Manila (Tire Testing)
  • BPS Testing Center, CMDC Compound, Carlos Trinidad Ave., Salawag, Dasmarinas City, Cavite, Philippine (Tube Testing)
  • Q-Tech Testing Laboratory, No 29G. Raymundo St., Bo. Molinao, Pasig City, Metro Manila, Philippine (Tube testing)

Sampling Sizes: per Plant and per Brand

  • PCR: Total 5 PCS Required as below:
    • 1st sample is for dimensional testing & plunger testing In-house (factory lab)
    • 2nd sample is for high speed testing in-house
    • 3rd sample is for endurance testing in-house 
    • 4th sample is for Plunger test & dimensional testing @ PGA Manila
    • 5th sample is for safekeeping as reference sample (kept by the factory)
  • LTR & TBR: Total 4 PCS Required as follows
    • 1st sample is for dimensional & plunger testing
    • 2nd sample is for endurance testing
    • 3rd sample is for Plunger testing & dimensional testing @ PGA Manila
    • 4th sample is for safekeeping as reference sample (kept by the factory)
  • Inner Tubes: Total 4 PCS Required as follows
    • 1st sample is for dimensional test and other tests required by PNS 34;1-2019; in-house (factory lab)
    • 2nd sample is for Q-Tech lab testing in Manila
    • 3rd and 4th sample is kept at the factory as a reference sample (Just in case sample sent to Q-TECH failed and requires re-testing) (For Tubes, in case of failure, it is allowed to re-testing by using the 3rd & 4th reference samples)

Timeline of PS Quality Mark Licenses

Approximately 3 to 4 Months after Application of PS Mark’ Audit (Depending on Test center’ workloads)

Alternate Text

Call To Action

Looking to get the certification that will validate your product? Connect to ERA we are here at your service.

Call To Action

Contact Us

Address

1407,14th Floor, RG Trade Tower
Netaji Subhash Place, Pitampura,New Delhi-34

Phone Number

011- 45151636

Your message has been sent. Thank you!